Effect of intelligent wearable rehabilitation system on rehabilitation training after knee joint replacement
Qi Pan1, Zhao Zhixin2, Jia Bin2 , Liu Kemin1
1 Arthropathy Diagnosis and Treatment Center, China Rehabilitation Center Beijing Boai Hospital, Beijing 100068, China; 2Department of Orthopaedics, Beijing DCN Orthopaedic Hospital, Beijing 100143, China Qi Pan and Zhao Zhixin contributed equally to the article
Abstract:Objective To explore the clinical application value of intelligent wearable rehabilitation system in rehabilitation after total knee arthroplasty (TKA).Methods Prospective study. The 120 patients from Beijing Boai Hospital treated by TKA from October 2017 to April 2018 were enrolled, including 15 males and 69 females, aged from 55 to 78 years old, body mass index(BMI) from 19.7 to 32.6 kg/m2. Preoperative range of motion(ROM) from 84° to 117°, K-L grading Ⅲ 42 patients, Ⅳ 78 patients. The random number method was applied to divide 60 patients into control group and 60 patients into treatment group. During hospitalization and post-discharge, the control group was trained according to the doctor's advice and on-time review, while the treatment group used the NEO-SMART system for postoperative training.The pain visual analogue scale (VAS), knee range of motion (ROM) and knee HSS score of two groups were observed at different time points after surgery.Results There was no significant difference in gender, age, BMI and K-L grading between the two groups(all P values>0.05). Among the 120 patients, 4 patients were lost in follow-up, others were followed up for 6 months. No significant differences in VAS were noted between two groups at 48 h after operation (P>0.05). At 2 weeks and 1 month after surgery, VAS in the rehabilitation group was lower than that in the control group (2.2±0.61) and (1.2±0.37) scores in the rehabilitation group and (2.5±0.82) and (1.7±0.53) scores in the control group, respectively, with statistically significant differences (all P values<0.05). The ROM scores of two groups were not significantly different at 48 h and 1 week after operation (P>0.05), At 2 weeks, 1 month, and 3 months postoperatively, the knee joint ROM was higher in the treatment group(93.1°±3.07°,103.5°±3.47°,107.3°±4.33°) than the control group (88.7°±3.60°, 96.8°±3.76°, 99.8° ± 4.05°), there were statistical differences(all P values<0.01). The HSS scores of the treatment group were significantly higher than the control group at 1 month, 3 months and 6 months after surgery (all P values<0.01).Conclusions Wearable rehabilitation system can significantly improve the effect of rehabilitation training for TKA patients after operation, which is worthy of clinical application.
亓攀, 赵志昕, 贾斌, 刘克敏. 智能可穿戴康复系统在膝关节置换术后康复训练中的应用效果[J]. 中华解剖与临床杂志, 2019, 24(6): 560-563.
Qi Pan, Zhao Zhixin, Jia Bin,Liu Kemin. Effect of intelligent wearable rehabilitation system on rehabilitation training after knee joint replacement. Chinese Journal of Anatomy and Clinics, 2019, 24(6): 560-563.
Escamilla RF, Macleod TD, Wilk KE, et al. Anterior cruciate ligament strain and tensile forces for weight-bearing and non-weight-bearing exercises: a guide to exercise selection[J]. J Orthop Sports Phys Ther, 2012, 42(3): 208-220. DOI:10.2519/jospt.2012.3768.
[3]
Seil R., Pape D. Causes of failure and etiology of painful primary total knee arthroplasty[J]. Knee Surg Sports Traumatol Arthrosc, 2011, 19(9): 1418-1432. DOI:10.1007/s00167-011-1631-9.
Choi WC, Ryu KJ, Lee S, et al. Painful patellar clunk or crepitation of contemporary knee prostheses[J]. Clin Orthop Relat Res, 2013, 471(5): 1512-1522. DOI:10.1007/s11999-012-2652-5.
[13]
Brennan GP, Fritz JM, Houck LT, et al. Outpatient rehabilitation care process factors and clinical outcomes among patients discharged home following unilateral total knee arthroplasty[J]. J Arthroplasty, 2015, 30(5): 885-890. DOI:10.1016/j.arth.2014.12.013.
[14]
Hawker GA. Who, when, and why total joint replacement surgery? The patient’s perspective[J]. Curr Opin Rheumatol, 2006, 18(5): 526-530. DOI: 10.1097/01.bor.0000240367.62583.51.
[15]
Keijsers R, van den Bekerom M, van Delft R, et al. Continuous local infiltration analgesia after TKA: a Meta-analysis[J]. J Knee Surg, 2016, 29(4): 310-321. DOI:10.1055/s-0035-1556843.
Monticone M, Capone A, Frigau L, et al. Development of the Italian version of the High-Activity Arthroplasty Score (HAAS-I) following hip and knee total arthroplasty: cross-cultural adaptation, reliability, validity and sensitivity to change[J]. J Orthop Surg Res, 2018, 13: 81. DOI:10.1186/s13018-018-0782-5.
[20]
Akil S, Newman JM, Shah NV, et al. Metal hypersensitivity in total hip and knee arthroplasty: current concepts[J]. J Clin Orthop Trauma, 2018, 9(1): 3-6. DOI:10.1016/j.jcot.2017.10.003.