Abstract:Objective To study the accuracy of robot-assisted pedicle screws placement and to observe the complications relate to the placement of pedicle screws.Methods From December 2014 to May 2015, robotic-assisted screw placement was used in 13 patients (6 males and 7 females), including 2 cases of from L1 burst fracture, 1 case of L2 compression fracture in 1 case, 4 cases of L4 spondylolisthesis, 1 case of T12 bursting fracture with paraplegia, 1 case of L1 old compression fracture with kyphosis, 1 case of degenerative scoliosis, 1 case of congenital scoliosis revision, 1 case of lumbar intervertebral disc herniation with spinal stenosis and 1 case of sequela of poliomyelitis scoliosis. The mean age of the patients was 56.5 years old (range, 41-73). The accuracy of placement of the pedicle screws was evaluated according to the classification of Gertzbein and Robbins.Results Robotic-guided screw placement was successfully used in 12 out of 13 patients. In those 12 patients, 83 screws (84 planned screws) were successfully implanted. One screw was manually placed due to poor registration. According to classification of Gertzbein and Robbins, 80 screws belonged to grade A, 2 belonged to grade B, 1 belonged to grade C. And the rate of the accuracy of pedicle screws placement was 98.8%(82/83). There was no complication such as nerve root, spinal cord and vessel injury resulted from pedicle screws placement.Conclusions The accuracy of robot-assisted pedicle screws placement is high. And it can reduce or avoid the complications resulted from pedicle screws placement.
干旻峰,杨惠林,周峰,陆俭,孟斌,毛海青,姜为民,杨炎,钮俊杰. 机器人辅助椎弓根螺钉置钉的准确性观察[J]. 中华解剖与临床杂志, 2016, 21(4): 326-330.
Gan Minfeng, Yang Huilin, Zhou Feng, Lu Jian, Meng Bin, Mao Haiqing, Jiang Weimin, Yang Yan, Niu Junjie. Accuracy of robot-assisted pedicle screws placement. Chinese Journal of Anatomy and Clinics, 2016, 21(4): 326-330.
Lonstein JE, Denis F, Perra JH, et al. Complications associated with pedicle screws[J]. J Bone Joint Surg Am, 1999, 81(11): 1519-1528
[2]
Devito DP, Kaplan L, Dietl R, et al. Clinical acceptance and accuracy assessment of spinal implants guided with SpineAssist surgical robot: retrospective study[J]. Spine(Phila Pa 1976), 2010, 35(24): 2109-2115. DOI:10.1097/BRS.0b013e3181d323ab
[3]
Pechlivanis I, Kiriyanthan G, Engelhardt M, et al. Percutaneous placement of pedicle screws in the lumbar spine using a bone mounted miniature robotic system: first experiences and accuracy of screw placement[J]. Spine(Phila Pa 1976), 2009, 34(4): 392-398. DOI:10.1097/BRS.0b013e318191ed32
[4]
Shoham M, Burman M, Zehavi E, et al. Bone-mounted miniature robot for surgical procedures: concept and clinical applications[J]. IEEE Trans Robot Automat, 2003, 19(5): 893-901. DOI:10.1109/tra.2003.817075
[5]
Barzilay Y, Schroeder JE, Hiller N, et al. Robot-assisted vertebral body augmentation: a radiation reduction tool[J]. Spine(Phila Pa 1976), 2014, 39(2): 153-157. DOI:10.1097/BRS.0000000000000100
[6]
Gertzbein SD, Robbins SE. Accuracy of pedicular screw placement in vivo[J]. Spine(Phila Pa 1976), 1990, 15(1): 11-14
[7]
杨惠林, Yuan HA, 陆俭, 等. 球囊扩张椎体后凸成形术治疗骨质疏松性椎体压缩骨折[J]. 苏州大学学报:医学版, 2002, 22(4): 406-409
Jutte PC, Castelein RM. Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations[J]. Eur Spine J, 2002, 11(6): 594-598. DOI:10.1007/s00586-002-0469-80
[11]
Laine T, Lund T, Ylikoski M, et al. Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients[J]. Eur Spine J, 2000, 9(3): 235-240. DOI: 10.1007/s005860000146
[12]
Steinmann JC, Herkowitz HN, el-Kommos H, et al. Spinal pedicle fixation. Confirmation of an image-based technique for screw placement[J]. Spine(Phila Pa 1976), 1993, 18(13): 1856-1861
[13]
Kosmopoulos V, Schizas C. Pedicle screw placement accuracy: a meta-analysis[J]. Spine(Phila Pa 1976), 2007, 32(3): E111-E120. DOI:10.1097/01.brs.0000254048.79024.8b
[14]
Tian NF, Xu HZ. Image-guided pedicle screw insertion accuracy: a meta-analysis[J]. Int Orthop, 2009, 33(4): 895-903. DOI:10.1007/s00264-009-0792-3
[15]
Wang T, Luan S, Hu L, et al. Force-based control of a compact spinal milling robot[J]. Int J Med Robot, 2010, 6(2): 178-185. DOI:10.1002/rcs.304
Hu X, Ohnmeiss DD, Lieberman IH. Robotic-assisted pedicle screw placement: lessons learned from the first 102 patients[J]. Eur Spine J, 2013, 22(3): 661-666. DOI:10.1007/s00586-012-2499-1
[20]
Kim HJ, Lee SH, Chang BS, et al. Monitoring the quality of robot-assisted pedicle screw fixation in the lumbar spine by using a cumulative summation test[J]. Spine(Phila Pa 1976), 2015, 40(2): 87-94. DOI:10.1097/BRS.0000000000000680
[21]
Schatlo B, Molliqaj G, Cuvinciuc V, et al. Safety and accuracy of robot-assisted versus fluoroscopy-guided pedicle screw insertion for degenerative diseases of the lumbar spine: a matched cohort comparison[J]. Neurosurg Spine, 2014, 20(6): 636-643. DOI:10.3171/2014.3. SPINE13714
[22]
Roser F, Tatagiba M, Maier G. Spinal robotics: current applications and future perspectives[J]. Neurosurgery, 2013, 72 Suppl 1: 12-18. DOI:10.1227/NEU.0b013e318270d02c
[23]
Schizas C, Thein E, Kwiatkowski B, et al. Pedicle screw insertion: robotic assistance versus conventional C-arm fluoroscopy[J]. Acta Orthop Belg, 2012, 78(2): 240-245
[24]
Kantelhardt SR, Martinez R, Baerwinkel S, et al. Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placement[J]. Eur Spine J, 2011, 20(6): 860-868. DOI:10.1007/s00586-011-1729-2
[25]
van Dijk JD, van den Ende RP, Stramigioli S, et al. Clinical pedicle screw accuracy and deviation from planning in robot-guided spine surgery: robot-guided pedicle screw accuracy[J]. Spine(Phila Pa 1976), 2015, 40(17): E986-E991. DOI:10.1097/BRS.0000000000000960
[26]
Lonjon N, Chan-Seng E, Costalat V, et al. Robot-assisted spine surgery: feasibility study through a prospective case-matched analysis[J]. Eur Spine J, 2016, 25(3): 947-955. DOI:10.1007/s00586-015-3758-8
[27]
Hu X, Lieberman IH. What is the learning curve for robotic-assisted pedicle screw placement in spine surgery[J]. Clin Orthop Relat Res, 2014, 472(6): 1839-1844. DOI:10.1007/s11999-013-3291-1