Abstract:Objective To review and summarize the research progress on biomechanics, incidence and influencing factors of facet joints violation by pedicle screw in lumbar interbody fusion.Methods The researches related to facet joint violation by pedicle screw were searched in Pubmed, SpringerLink, Medline, CNKI and Wanfang database from January 2003 to December 2015 by using “lumbar interbody fusion, pedicle screw, facet joint violation” as key words.Results Facet joint was an important structure for stability of lumbar spine, injury could lead facet joint contracture, stiffness and osteoarthritis, which eventually accelerated the incidence of adjacent segment degeneration. Surgical trauma was an important factor causing the facet joint violation, especially the insertion of pedicle screw in operation. Facet joint had a higher incidence of injury in both open and minimally invasive pedicle screw insertion. The factors affecting pedicle screw damage facet joints included: age, sex, weight, fusion segment, fusion number, operation method, intraoperative CT navigation, and so on.Conclusions Facet joint violation is an important risk factor which leads to adjacent segment degeneration. Insertion of pedicle screw in operation is an important factor causing the facet joint violation in both open and minimally invasive surgery. Surgeons should pay more attention to the facet joints protection in lumbar fusion surgery, especially in the insertion of pedicle screws.
Rao RD, David KS, Wang M. Biomechanical changes at adjacent segments following anterior lumbar interbody fusion using tapered cages[J]. Spine (Pilila Pa 1976), 2005, 30(24): 2772-2776. DOI: 10.1097/01.brs.0000190813.27468.2d
[2]
Lee CS, Hwang CJ, Lee SW, et al. Risk factors for adjacent segment disease after lumbar fusion[J]. Eur Spine J, 2009, 18(11): 1637-1643. DOI: 10.1007/s00586-009-1060-3
[3]
Lerner T, Frobin W, Bullmann V, et al. Changes in disc height and posteroanterior displacement after fusion in patients with idiopathic scoliosis: a 9-year follow-up study[J]. J Spinal Discord Tech, 2007, 20(3): 195-202. DOI: 10.1097/01.bsd.0000211269.51368.95
[4]
Rahm MD, Hall BB. Adjacent-segment degeneration after lumbar fusion with instrumentation: a retrospective study[J]. J Spinal Disord, 1996, 9(5): 392-400
[5]
Pellisé F, Hernández A, Vidal X, et al. Radiologic assessment of on unfused lumber segments 7.5 years after instrumented posterior spinal fusion spine[J]. Spine (Phila Pa 1976), 2007, 32(5): 574-579. DOI: 10.1097/01.brs.0000256875.17765.e6
[6]
Park P, Carton HJ, Gala VC, et al. Adjacent segment disease after lumbar or lumbosacral fusion:review of the literature[J]. Spine (Phila Pa 1976), 2004, 29(17): 1938-1944. DOI: 10.1097/01.brs.0000137069.88904.03
Van Schaik JP, Verbiest H, Van Schaik FD, The orientation of laminae and facet joints in the lower lumbar spine[J]. Spine (Phila Pa 1976), 1985, 10(1): 59-63
[10]
Varlotta GP, Lefkowitz TR, Schweitzer M, et al. The lumbar facet joint: a review of current knowledge: part 1: anatomy, biomechanics, and grading[J]. Skeletal Radiol, 2011, 40(1): 13-23. DOI:10.1007/s00256-010-0983-4
Tachihara H, Kikuchi S, Konno S, et al. Does facet joint inflammation induce radiculopathy?: an investigation using a rat model of lumbar facet joint inflammation[J]. Spine(Phila Pa 1976), 2007, 32(4): 406-412. DOI: 10.1097/01.brs.0000255094.08805.2f
[15]
Rankine JJ, Dickson RA. Unilateral spondylolysis and the presence of facet joint tropism[J]. Spine (Phila Pa 1976), 2010, 35(21): E1111-1114. DOI: 10.1097/BRS.0b013e3181de8b72
[16]
Schulte TL, Hurschler C, Haversath M, et al. The effect of dynamic, semi-rigid implants on the range of motion of lumbar motion segments after decompression[J]. Eur Spine J, 2008, 17(8): 1057-1065. DOI: 10.1007/s00586-008-0667-0
[17]
Kim HJ, Chun HJ, Kang KT, et al.The biomechanical effect of pedicle screws' insertion angle and position on the superior adjacent segment in 1 segment lumbar fusion[J]. Spine (Phila Pa 1976), 2012, 37(19): 1637-1644. DOI: 10.1097/BRS.0b013e31823f2115
[18]
Cardoso MJ, Dmitriev AE, Helgeson M, et al. Does superior-segment facet violation or laminectomy destabilize the adjacent level in lumbar transpedicular fixation?An in vitro human cadaveric assessment[J]. Spine (Phila Pa 1976), 2008, 33(26): 2868-2873. DOI: 10.1097/BRS.0b013e31818c63d3
[19]
Knox J, Dai JM 3rd, Orchowski JR. Superior segment facet joint violation and cortical violation after minimally invasive pedicle screw placement[J]. Spine J, 2011, 11(3): 213-217. DOI: 10.1016/j.spinee.2011.01.024
[20]
Patel RD, Graziano GP, Vanderhave KL, et al. Facet violation with the placement of percutaneous pedicle screws[J]. Spine (Phila Pa 1976), 2011, 36: E1749-E1752. DOI: 10.1097/BRS.0b013e318221a800
[21]
Park Y, Ha JW, Lee YT, et al. Cranial facet joint violations by percutaneously placed pedicle screws adjacent to a minimally invasive lumbar spinal fusion[J]. Spine J, 2011, 11(4): 295-302. DOI: 10.1016/j.spinee.2011.02.007
[22]
Shah RR, Mohammed S, Saifuddin A, et.al. Radiologic evaluation of adjacent superior segment facet joint violation following transpedicular instrumentation of the lumbar spine[J]. Spine (Phila Pa 1976), 2003, 28(3): 272-275. DOI: 10.1097/00007632-200302010-00013
[23]
Moshidar A, Jenis LG, Spector LR, et al. Computed tomography evaluation of superior-segment foeet-joint violation after pedicle instrumentation of the lumbar spine with a midline surgical approach. [J]. Spine (Phila Pa 1976), 2006, 31(22): 2624-2629. DOI: 10.1097/01.brs.0000240691.35707.e8
[24]
Chen Z, Zhao J, Xu H, et al. Technical factors related to the incidence of adjacent superior segment facet joint violation after transpedicular instrumentation in the lumbar spine[J]. Eur Spine J, 2008, 17(11): 1476-1480. DOI: 10.1007/s00586-008-0776-9
[25]
Babu R, Park JG, Mehta AI, et al. Comparison of superior-level facet joint violations during open and percutaneous pedicle screw placement[J]. Neurosurgery, 2012, 71(5): 962-970. DOI: 10.1227/NEU.0b013e31826a88c8
[26]
Lau D, Terman SW, Patel R, et al. Incidence of and risk factors for superior facet violation in minimally invasive versus open pedicle screw placement during transforaminal lumbar interbody fusion: a comparative analysis[J]. J Neurosurg Spine, 2013, 18(14): 356-361. DOI: 10.3171/2013.1.SPINE12882
[27]
Zeng ZL, Jia L, Xu W, et al. Analysis of risk factors for adjacent superior vertebral pedicle-induced facet joint violation during the minimally invasive surgery transforaminal lumbar interbody fusion: a retrospective study[J]. Eur J Med Res, 2015, 20: 80. DOI: 10.1186/s40001-015-0174-9
Jones-Quaidoo SM, Djurasovic M, Owens RK 2nd et al. Superior articulating facet violation: percutaneous versus open techniques[J]. J Neurosurg Spine, 2013, 18(6): 593-597. DOI: 10.3171/2013.3.SPINE12829
[30]
Wang L, Wang YP ,Yu B, et al. Comparison of cranial facet joint violation rate between percutaneous and open pedicle screw placement, a systematic review and meta-Analysis[J]. Medicine (Baltimore), 2015, 94(5): e504. DOI: 10.1097/MD.0000000000000504
[31]
Yson SC, Sembrano JN, Sanders PC, et al. Comparison of cranial facet joint violation rates between open and percutaneous pedicle screw placement usingintraoperative 3-D CT (O-arm) computer navigation[J]. Spine (Phila Pa 1976), 2013, 38(4): E251-258. DOI: 10.1097/BRS.0b013e31827ecbf1
[32]
Tian W, Xu Y, Liu B, et al. Lumbar spine superior-level facet joint violations: percutaneous versus open pedicle screw insertion using intraoperative 3-dimensional computer-assisted navigation[J]. Chin Med J (Engl), 2014, 127(22):3852-3856.DOI: 10.3760/cma.j.issn.0366-6999.20141860