Abstract:Although the application of megaprosthesis has maturely progressed, complications of aseptic loosening, breakage, and infection could not be satisfactorily solved and prominently influence the therapeutic effect and prognosis of patients. The development of biological materials, surface processing techniques, and biomechanics theoretically supports the improvement of megaprosthesis design. The present orientation which is focused on includes the improvement of surface coating technics for megaprosthesis, application of antibacterial processing which could decrease the occurrence of infection and amelioration of fixation by the optimization of structural design.
通讯作者:
郭卫,主任医师,教授,博士生导师。现任北京大学人民医院骨肿瘤诊疗中心主任,北京大学人民医院骨科教研室主任,骨肿瘤研究室主任。亚太地区骨肿瘤学会(APMSTS)前任主席,国际保肢学会(ISOLS)前任主席,国际骶骨骨盆肿瘤研究协作组主席,儿童肿瘤协作组(COG)成员,东亚骨与软组织肿瘤研究协作组(EMOG)成员,国际结缔组织肿瘤协会成员,中华医学会骨科学分会骨肿瘤学组组长(2005—2017年),中华医学会肿瘤学分会骨肿瘤学组组长,中华医学会骨科学分会委员,中国医师学会骨科分会常委,中国医师学会骨科分会骨肿瘤专业委员会主任委员,J Bone and Joint Surg副主编,Chinese Medical Journal编委、《中华骨科杂志》编委、《中华外科杂志》编委、Journal of Orthopaedic Science编委等。担任多项国家级科研项目、国际合作项目负责人。获得各类奖项10项,主持原发恶性骨肿瘤的规范化切除及功能重建的系列研究获得国家科技进步二等奖。近年来共发表300余篇高水平论文,其中SCI收录100余篇,主编了世界范围内第一部关于骨盆环肿瘤切除重建技术的专著《骨盆肿瘤外科学》。主持制定了骨肉瘤、软骨肉瘤、骨巨细胞瘤、尤文肉瘤和骨髓瘤的循证医学诊疗指南。Email:bonetumor@163.com
引用本文:
郭卫. 肿瘤型人工关节假体的发展现状及优化策略[J]. 中华解剖与临床杂志, 2022, 27(3): 129-137.
Guo Wei. Development status and optimization strategy of megaprosthesis prosthesis. Chinese Journal of Anatomy and Clinics, 2022, 27(3): 129-137.
Haijie L, Dasen L, Tao J, et al. Implant survival and complication profiles of endoprostheses for treating tumor around the knee in adults: a systematic review of the literature over the past 30 years[J]. J Arthroplasty, 2018, 33(4):1275-1287.e3. DOI: 10.1016/j.arth.2017.10.051.
[2]
Henderson ER, Groundland JS, Pala E, et al.Failure mode classification for tumor endoprostheses: retrospective review of five institutions and a literature review[J]. J Bone Joint Surg Am, 2011, 93(5):418-429.
[3]
Gallo J, Goodman SB, Konttinen YT, et al.Osteolysis around total knee arthroplasty: a review of pathogenetic mechanisms[J]. Acta Biomater, 2013,9(9):8046-8058. DOI: 10.1016/j.actbio.2013.05.005.
[4]
Herrera A, Mateo J, Lobo-Escolar A, et al.Long-term outcomes of a new model of anatomical hydroxyapatite-coated hip prosthesis[J]. J Arthroplasty, 2013,28(7):1160-1166. DOI: 10.1016/j.arth.2012.06.033.
[5]
Long M, Rack HJ.Titanium alloys in total joint replacement--a materials science perspective[J]. Biomaterials, 1998, 19(18):1621-1639. DOI: 10.1016/s0142-9612(97)00146-4.
[6]
Semlitsch M, Willert HG.Implant materials for hip endoprostheses: old proofs and new trends[J]. Arch Orthop Trauma Surg, 1995,114(2):61-67. DOI: 10.1007/BF00422826.
Duda GN, Elias JJ, Valdevit A, et al.Locking strength of Morse tapers used for modular segmental bone defect replacement prostheses[J]. Biomed Mater Eng, 1997,7(4):277-284.
[9]
郭卫, 梁海杰, 杨毅, 等. 仿生肿瘤型膝关节假体重建儿童股骨远端骨肉瘤切除后骨缺损[J].中华骨科杂志,2021,41(4):201-210. DOI: 10.3760/cma.j.cn121113-20201201-00697.Guo W, Liang HJ, Yang Y, et al.Reconstruction with a bionic knee megaprosthesis after resection of a distal femoral osteosarcoma in children[J]. Chin J Orthop,2021,41(4):201-210. DOI: 10.3760/cma.j.cn121113-20201201-00697.
[10]
Sharma S, Turcotte RE, Isler MH, et al.Cemented rotating hinge endoprosthesis for limb salvage of distal femur tumors[J]. Clin Orthop Relat Res, 2006,450:28-32. DOI: 10.1097/01.blo.0000229316.66501.fc.
[11]
Chao EY, Sim FH.Modular prosthetic system for segmental bone and joint replacement after tumor resection[J]. Orthopedics, 1985, 8(5):641-651.
[12]
Sharma S, Turcotte RE, Isler MH, et al.Experience with cemented large segment endoprostheses for tumors[J]. Clin Orthop Relat Res, 2007, 459:54-59. DOI: 10.1097/BLO.0b013e3180514c8e.
[13]
Ward WG, Johnston KS, Dorey FJ, et al.Extramedullary porous coating to prevent diaphyseal osteolysis and radiolucent lines around proximal tibial replacements. A preliminary report[J]. J Bone Joint Surg Am, 1993,75(7):976-987. DOI: 10.2106/00004623-199307000-00003.
[14]
Herrera A, Mateo J, Lobo-Escolar A, et al.Long-term outcomes of a new model of anatomical hydroxyapatite-coated hip prosthesis[J]. J Arthroplasty, 2013,28(7):1160-1166. DOI: 10.1016/j.arth.2012.06.033.
[15]
Park E, Sr CRA, Hoelzer DT, et al.Interfacial characterization of plasma-spray coated calcium phosphate on Ti-6Al-4V[J]. J Mater Sci Mater Med, 1998,9(11):643-649. DOI: 10.1023/a:1008931508465.
[16]
Wren A, Akgun B, Adams B, et al.Characterization and antibacterial efficacy of silver-coated Ca-Na-Zn-Si/Ti glasses[J]. J Biomater Appl, 2012,27(4):433-443. DOI: 10.1177/0885328211411000.
[17]
Warburton A, Girdler SJ, Mikhail CM, et al.Biomaterials in spinal implants: a review[J]. Neurospine, 2020,17(1):101-110. DOI: 10.14245/ns.1938296.148.
[18]
Matsuno H, Yokoyama A, Watari F, et al.Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium[J]. Biomaterials, 2001,22(11):1253-1262. DOI: 10.1016/s0142-9612(00)00275-1.
[19]
Findlay DM, Welldon K, Atkins GJ, et al.The proliferation and phenotypic expression of human osteoblasts on tantalum metal[J]. Biomaterials, 2004,25(12):2215-2227. DOI: 10.1016/j.biomaterials.2003.09.005.
[20]
Fernández-Fairen M, Sala P, Dufoo M, et al.Anterior cervical fusion with tantalum implant: a prospective randomized controlled study[J]. Spine (Phila Pa 1976), 2008,33(5):465-472. DOI: 10.1097/BRS.0b013e3181657f49.
[21]
Nakashima Y, Mashima N, Imai H, et al.Clinical and radiographic evaluation of total hip arthroplasties using porous tantalum modular acetabular components: 5-year follow-up of clinical trial[J]. Mod Rheumatol, 2013,23(1):112-118. DOI: 10.1007/s10165-012-0618-9.
[22]
Guo Y, Xie K, Jiang W, et al.In vitro and in vivo study of 3D-printed porous tantalum scaffolds for repairing bone defects[J]. ACS Biomater Sci Eng, 2019,5(2):1123-1133. DOI: 10.1021/acsbiomaterials.8b01094.
[23]
Langlais F, Belot N, Ropars M, et al.The long-term results of press-fit cemented stems in total knee prostheses[J]. J Bone Joint Surg Br, 2006,88(8):1022-1026. DOI: 10.1302/0301-620X.88B8.17722.
[24]
Song B, Zhao X, Li S, et al.Differences in microstructure and properties between selective laser melting and traditional manufacturing for fabrication of metal parts: a review[J]. Front Mech Eng, 2015,10(2):111-125. DOI: 10.1007/s11465-015-0341-2.
[25]
Xiu P, Jia Z, Lv J, et al.Tailored surface treatment of 3D printed porous Ti6Al4V by microarc oxidation for enhanced osseointegration via optimized bone in-growth patterns and interlocked bone/implant interface[J]. ACS Appl Mater Interfaces, 2016,8(28):17964-17975. DOI: 10.1021/acsami.6b05893.
[26]
Shah FA, Snis A, Matic A, et al.3D printed Ti6Al4V implant surface promotes bone maturation and retains a higher density of less aged osteocytes at the bone-implant interface[J]. Acta Biomater, 2016,30:357-367. DOI: 10.1016/j.actbio.2015.11.013.
[27]
Palmquist A, Shah FA, Emanuelsson L, et al.A technique for evaluating bone ingrowth into 3D printed, porous Ti6Al4V implants accurately using X-ray micro-computed tomography and histomorphometry[J]. Micron, 2017,94:1-8. DOI: 10.1016/j.micron.2016.11.009.
[28]
Manoso MW, Boland PJ, Healey JH, et al. Limb salvage of infected knee reconstructions for cancer with staged revision and free tissue transfer[J]. Ann Plast Surg, 2006,56(5):532-535; discussion 535. DOI: 10.1097/01.sap.0000203990.08414.ad.
[29]
Nair LS, Laurencin CT. Nanofibers and nanoparticles for orthopaedic surgery applications[J]. J Bone Joint Surg Am, 2008, 90 Suppl 1:128-131. DOI: 10.2106/JBJS.G.01520.
[30]
Furno F, Morley KS, Wong B, et al.Silver nanoparticles and polymeric medical devices: a new approach to prevention of infection?[J]. J Antimicrob Chemother, 2004,54(6):1019-1024. DOI: 10.1093/jac/dkh478.
[31]
Ghani Y, Coathup MJ, Hing KA, et al.Development of a hydroxyapatite coating containing silver for the prevention of peri-prosthetic infection[J]. J Orthop Res, 2012,30(3):356-363. DOI: 10.1002/jor.21543.
[32]
Shirai T, Tsuchiya H, Nishida H, et al.Antimicrobial megaprostheses supported with iodine[J]. J Biomater Appl, 2014,29(4):617-623. DOI: 10.1177/0885328214539365.
[33]
Tsuchiya H, Shirai T, Nishida H, et al.Innovative antimicrobial coating of titanium implants with iodine[J]. J Orthop Sci, 2012,17(5):595-604. DOI: 10.1007/s00776-012-0247-3.
[34]
Corona, PS, Barro, V, Mendez, M, et al.Industrially prefabricated cement spacers: do vancomycin- and gentamicin-impregnated spacers offer any advantage?[J]. Clin Orthop Relat Res, 2014,472(3):923-32. DOI: 10.1007/s11999-013-3342-7.
[35]
Takigami I, Ito Y, Ishimaru D, et al.Two-stage revision surgery for hip prosthesis infection using antibiotic-loaded porous hydroxyapatite blocks[J]. Arch Orthop Trauma Surg, 2010,130(10):1221-1226. DOI: 10.1007/s00402-009-0991-9.
[36]
Ji T, Yang Y, Tang X, et al.3D-Printed modular hemipelvic endoprosthetic reconstruction following periacetabular tumor resection: early results of 80 consecutive cases[J]. J Bone Joint Surg Am, 2020,102(17):1530-1541. DOI: 10.2106/JBJS.19.01437.
[37]
Arabnejad S, Johnston B, Tanzer M, et al.Fully porous 3D printed titanium femoral stem to reduce stress-shielding following total hip arthroplasty[J]. J Orthop Res, 2017,35(8):1774-1783. DOI: 10.1002/jor.23445.